Hantek DSO8202E 2 Channels 200Mhz Digital Oscilloscope

$999.99
  • DSO8000E Series

    Six in one: Oscilloscope/Recorder/DMM/ Spectrum Analyzer/Frequency Counter/Arbitrary Waveform generator. IP-51 rated for dust, drip and shake proof to withstand harsh environments. Large fuse confirms to European Safety Standard. Battery indicator with easy-changed connect points. Selectable 18650 battery box for matching 18650 battery by yourself. Anti-theft lock hole, tripod fixed hole, hang rope, FLASH light that can be used in darkness. Replaceable BNC safety joints, and additional one set of joints. 1GSa/s sample rate, 2M Memory depth, 6000 counts DMM. Large 5.6 inch TFT Color LCD Display; High Resolution(640*480)

    Features:

    • Six in one: Oscilloscope/Recorder/DMM/ Spectrum Analyzer/Frequency Counter/Arbitrary Waveform generator.
    • IP-51 rated for dust, drip and shake proof to withstand harsh environments.
    • Large fuse confirms to European Safety Standard.
    • Battery indicator with easy-changed connect points. Selectable 18650 battery box for matching 18650 battery by yourself.
    • Anti-theft lock hole, tripod fixed hole, hang rope, FLASH light that can be used in darkness.
    • Replaceable BNC safety joints, and additional one set of joints.
    • High bandwidth 70MHz-200MHz Oscilloscope, 1GSa/s sample rate, 2M Memory depth.
    • 25Mz Arb. Waveform Generator, 200 Mesa/s DDS, 12 bit vertical resolution, easy for simulating transducer
    • 6000 Counts DMM, AC/DC voltage, AC/DC current, resistance, break, capacitance, and diode function.
    • FFT spectral analysis; Waveform Math: add, subtract, multiply and divide; X-Y mode; more than 20 automatic measurements; PASS/FAIL Check function, apply to engineering application.
    • Abundant trigger function, double timebase sampling, easy to observe two waveforms in different frequency.
    • Record and replay of more than 1000 waveforms.
    • Large 5.6 inch TFT Color LCD Display; High Resolution(640*480)
    • USB Host/Device 2.0 full-speed interface; support removable disk;  WIFI/LAN Option, easy to control by PC or long-distance.
    • Waveform data can be output in WORD,EXCEL, BMP, JPG as time and voltage
    Model DSO8072E DSO8102E DSO8152E DSO8202E
    Acquisition
    Sample Modes Real-Time Sample
    Acquisition Modes
    Normal Normal data only
    Peak Detect High-frequency and randon glith capture
    Average Wavefom Average, selectable 4,8,16,32,64,128
    Inputs
    Inputs Coupling AC, DC, GND
    Inputs Impendance 1MΩ±2% ‖20pF±3pF
    Probe Attenuation 1X, 10X
    Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X
    Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category;
    CAT III: 150VRMS (1×)
    Horizontal System
    Sample Rate Range 1GS/s
    Waveform Interpolation (sin x)/x
    Record Length 2M
    SEC/DIV Range 4ns/div~2000s/div, in a  2, 4, 8 sequence 2ns/div~2000s/div, in a  2, 4, 8 sequence
    Sample Rate and
    Delay Time Accuracy
    ±50ppm over any ≥1ms time interval
    Scanning Speed Range 4ns/div to 8ns/div; (-8div x s/div) to 40ms;
    20ns/div to 80μs/div;(-8div×s/div) to 40ms;
    200μs/div to 40s/div;(-8div×s/div) to 400s;
    2ns/div to10ns/div;(-4div×s/div) to 20ms;
    Delta Time Measurement Accuracy
    (Full Bandwidth)
    Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
    >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
    Sample interval = s/div ÷ 200
    Vertical System
    Vertical Resolution 8-bit resolution, all channel sampled simultaneously
    Volts Range 2mV/div to 100V/div at input BNC
    Bandwidth 70MHz 100MHz 150MHz 200MHz
    Rise Time at BNC( typical) 5ns 3.5ns 2.3ns 1.8ns
    Analog Bandwidth in
    Normal and Average
    modes at BNC or with probe,
    DC Coupled
    ±400V(100V/div-20V/div); 
    ±50V(10V/div-5V/div);
    ±40V(2V/div-500mV/div);
    ±2V(200mV/div-50mV/div);
    ±400mV(20mV/div-2mV/div);
    Math +, -, *, /, FFT
    FFT Windows:  Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point
    Bandwidth Limit 20MHz
    Low Frequency Response (-3db) ≤10Hz at BNC
    DC Gain Accuracy ±3% for Normal or Average acquisition mode, 100V/div to 10mV/div.
    ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.
    DC Measurement Accuracy,
    Average Acquisition Mode
    Measurement Type: Average of 16 waveforms with vertical position at zero
    Accuracy: ± (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected.
    Measurement Type: Average of 
    16 waveforms with vertical position not at zero
    Accuracy: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div].
    Volts Measurement Repeatability,
    Average Acquisition Mode
    Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
    Trigger System
    Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative
    Trigger Source CH1, CH2, AC Line
    Trigger Modes Auto, Normal, Single
    Coupling Type DC, AC, HF Reject, LF Reject, Noise Reject
    Trigger Sensitivity
    (Edge Trigger Type)
    DC(CH1,CH2):
    1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
    AC: Attenuates signals below 10Hz ;
    HF Reject: Attenuates signals above 80kHz;
    LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz.  
    Trigger Level Range CH1/CH2: ±8 divisions from center of screen; 
    Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
    Set Level to 50%(typical) Operates with input signals ≥50Hz
    Video Trigger
    Video Trigger Type  CH1, CH2: Peak-to-peak amplitude of 2 divisions;
    Signal Formats and Field Rates Supports NTSC, PAL and SECAM broadcast systems for any field or any line
    Holdoff Range 100ns ~ 10s
    Pulse Width Trigger
    Pulse Width Trigger Mode Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
    Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
    Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
    Less than: The trigger point is the trailing edge.
    Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
    Pulse Width Range 20ns ~ 10s
    Slope Trigger
    Slope Trigger Mode Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
    Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
    Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
    Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
    Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
    Time Range 20ns ~ 10s
    Overtime Trigger
    Over Time Modee Rising edge or Falling edge
    Time Range 20ns ~ 10s
    Alternative Trigger
    Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope
    Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope
    Trigger Frequency Counter
    Readout Resolution 6 digits
    Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors)
    Frequency Range AC coupled, from 4Hz minimum to rated bandwidth
    Signal Source Pulse Width or Edge Trigger modes: all available trigger sources
    The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
    Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
    Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
    Video Trigger mode: The Frequency Counter does not work.
    Measure
    Cursor Measurement Manual: Voltage difference between cursors: V
                 Time difference between cursors: 
    T
                 Reciprocal of 
    T in Hertz (1/ΔT);
    Tracing: The valtage and time at a waveform point;
    Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS,
    Waveform Generator Mode
    Frenquency Range 1Hz(DC)~25MHz
    DAC Clock 2K~200MHz adjustable
    Memory Depth 4KSa
    Vertical Resolution 12 Bits
    Stability <30ppm
    Amplitude ±3.5V Max.
    Output Impedance 50 Ω
    Output Current 50mA Ipeak=50mA
    System Bandwidth 25M
    Harmonic Wave Distortion  -50dBc(1KHz),  -40dBc(10KHz)
    General Specifications
    Display Resolution 640 horizontal by 480 vertical pixels
    Display Contrast Adjustable (16 gears) with the progress bar
    Probe Compensator Output
    Output Voltage( typical) About 2Vpp into ≥1MΩ load
    Frequency(typical) 1kHz
    Power Supply
    Supply Voltage AC Input:100-240VACRMS,0.6A MAX,50Hz~60Hz; DC Output:9V,2A
    Power Consumption <30W
    Environmental
    Temperature Operating: 32℉ to 122℉ (0℃ to 50℃);
    Nonoperating: -40
     to 159.8℉ (-40℃ to +71℃)
    Cooling Method Convection
    Humidity +104℉ or below (+40℃ or below): ≤90% relative humidity;
    106
     to 122℉ (+41℃ to 50℃): ≤60% relative humidity
    Altitude Operating: Below 3,000m (10,000 feet);
    Nonoperaring: Below 15,000m(50,000 feet)
    Mechanical
    Size 260mmmm; 220mm; 75mm
    Weight 2.5KG(without Packing)
    DMM Mode
    Max. Resolution 6000 Counts
    DMM Testing Modes Voltage, Current, Resistance, Capacitance, Diode & Continuity
    Max. Input Voltage AC:600V, DC: 800V
    Max. Input Current AC: 10A, DC:10A
    Input Impedance 10MΩ
    DMM TrendPlot 1.2M  Point
    Range Resolution Accuracy Resolution
    DC Voltage 60.00mV ±1%±3 digit 10uV
    600.0mV 100uV
    6.000V 1mV
    60.00V 10mV
    600.0V 100mV
    800V 1V
    AC Voltage 60.00mV ±1%±3 digit 10uV
    600.0mV 100uV
    6.000V 1mV
    60.00V 10mV
    600.0V 100mV
    DC Current 60.00mA ±1%±5 digit 10uA
    600.0mA ±1.5%±5 digit 100uA
    6.000A 1mA
    10.00A 10mA
    AC Current 60.00mA ±1%±5 digit 10uA
    600.0mA ±1.5%±5 digit 100uA
    6.000A 1mA
    10.00A 10mA
    Resistance 600Ω ±1%±3 digit 0.1Ω
    6.000KΩ
    60.00KΩ 10Ω
    600.0KΩ 1KΩ
    6.000MΩ 10KΩ
    60.00MΩ ±1%±5 digit 100KΩ
    Capacitance 40.00nF ±2%±5 digit 10pF
    400.0nF 100pF
    4.000uF 1nF
    40.00uF 10nF
    400.0uF 100nF
    Attention: the smallest capacitance value that can be measured in 5nF
    Diode 0V~2.0V
    ON-OFF test <10Ω
×

Call for Price