{"product_id":"natural-gas-leak-detector-for-utility-pipeline-inspection","title":"Natural Gas Leak Detector for Utility Pipeline Inspection","description":"\u003cp data-start=\"155\" data-end=\"616\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"159\" data-end=\"199\"\u003eGOLIATH RN Natural Gas Leak Detector\u003c\/strong\u003e is a professional explosion-proof gas detection instrument designed for \u003cstrong data-start=\"272\" data-end=\"388\"\u003enatural gas utilities, pipeline operators, emergency response teams, and LDAR (Leak Detection \u0026amp; Repair) programs\u003c\/strong\u003e. Engineered for fast, reliable methane leak detection, it combines high-performance infrared sensing with an integrated diaphragm pump to quickly locate gas leaks, verify gas concentrations, and support safe utility operations.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"618\" data-end=\"1012\"\u003eIdeal for pipeline inspections, building surveys, bar hole testing, confined space monitoring, and gas purity verification, the GOLIATH RN also supports optional sensors for propane, oxygen, carbon monoxide, and gas flow velocity measurement. Its rugged ATEX-certified construction, large backlit display, and fast sensor response make it an excellent solution for demanding field environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1wnq3ka\" data-start=\"1014\" data-end=\"1036\"\u003eIdeal Applications\u003c\/h3\u003e\n\u003cul data-start=\"1037\" data-end=\"1255\"\u003e\n\u003cli data-section-id=\"1dqaw1\" data-start=\"1037\" data-end=\"1070\"\u003eNatural gas utility inspections\u003c\/li\u003e\n\u003cli data-section-id=\"zv527a\" data-start=\"1071\" data-end=\"1096\"\u003ePipeline leak detection\u003c\/li\u003e\n\u003cli data-section-id=\"ffjvuu\" data-start=\"1097\" data-end=\"1123\"\u003eBuilding gas inspections\u003c\/li\u003e\n\u003cli data-section-id=\"95aach\" data-start=\"1124\" data-end=\"1142\"\u003eBar hole testing\u003c\/li\u003e\n\u003cli data-section-id=\"kwcjk7\" data-start=\"1143\" data-end=\"1167\"\u003ePipeline commissioning\u003c\/li\u003e\n\u003cli data-section-id=\"zlhb7b\" data-start=\"1168\" data-end=\"1193\"\u003eGas purity verification\u003c\/li\u003e\n\u003cli data-section-id=\"dyvf1h\" data-start=\"1194\" data-end=\"1226\"\u003eLDAR (Leak Detection \u0026amp; Repair)\u003c\/li\u003e\n\u003cli data-section-id=\"1mrjpcy\" data-start=\"1227\" data-end=\"1255\"\u003eUtility emergency response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"1257\" data-end=\"1273\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1274\" data-end=\"1683\"\u003e\n\u003cli data-section-id=\"bcmzx0\" data-start=\"1274\" data-end=\"1315\"\u003eHigh-sensitivity methane leak detection\u003c\/li\u003e\n\u003cli data-section-id=\"490k6p\" data-start=\"1316\" data-end=\"1354\"\u003eMeasures methane in ppm and % volume\u003c\/li\u003e\n\u003cli data-section-id=\"1lu6gsp\" data-start=\"1355\" data-end=\"1391\"\u003eIntegrated diaphragm sampling pump\u003c\/li\u003e\n\u003cli data-section-id=\"1kqxawg\" data-start=\"1392\" data-end=\"1423\"\u003eFast methane and CO₂ response\u003c\/li\u003e\n\u003cli data-section-id=\"o5xmn1\" data-start=\"1424\" data-end=\"1479\"\u003eOptional propane, oxygen, and carbon monoxide sensors\u003c\/li\u003e\n\u003cli data-section-id=\"1fkwxo\" data-start=\"1480\" data-end=\"1520\"\u003eOptional gas flow velocity measurement\u003c\/li\u003e\n\u003cli data-section-id=\"8epgcx\" data-start=\"1521\" data-end=\"1568\"\u003eRugged ATEX-certified explosion-proof housing\u003c\/li\u003e\n\u003cli data-section-id=\"9jrx9a\" data-start=\"1569\" data-end=\"1596\"\u003eLarge backlit LCD display\u003c\/li\u003e\n\u003cli data-section-id=\"qy652m\" data-start=\"1597\" data-end=\"1637\"\u003eStores over \u003cstrong data-start=\"1611\" data-end=\"1624\"\u003e1 million\u003c\/strong\u003e measurements\u003c\/li\u003e\n\u003cli data-section-id=\"cy4qlc\" data-start=\"1638\" data-end=\"1665\"\u003eRechargeable NiMH battery\u003c\/li\u003e\n\u003cli data-section-id=\"1ekfey1\" data-start=\"1666\" data-end=\"1683\"\u003eMade in Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1685\" data-end=\"1688\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"1690\" data-end=\"1716\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1718\" data-end=\"2467\" class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 99.9677%; height: 386.818px;\"\u003e\n\u003cthead data-start=\"1718\" data-end=\"1743\"\u003e\n\u003ctr data-start=\"1718\" data-end=\"1743\" style=\"height: 19.5909px;\"\u003e\n\u003cth data-start=\"1718\" data-end=\"1734\" data-col-size=\"sm\" class=\"last:pe-10\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1734\" data-end=\"1743\" data-col-size=\"md\" class=\"last:pe-10\" style=\"width: 54.2727%; height: 19.5909px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1754\" data-end=\"2467\"\u003e\n\u003ctr data-start=\"1754\" data-end=\"1839\" style=\"height: 39.1818px;\"\u003e\n\u003ctd data-start=\"1754\" data-end=\"1773\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 39.1818px;\"\u003eDetectable Gases\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1773\" data-end=\"1839\" style=\"width: 54.2727%; height: 39.1818px;\"\u003eMethane (CH₄), Carbon Dioxide (CO₂), Optional Propane, O₂ \u0026amp; CO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1840\" data-end=\"1874\" style=\"height: 19.5909px;\"\u003e\n\u003ctd data-start=\"1840\" data-end=\"1856\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eMethane Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1856\" data-end=\"1874\" style=\"width: 54.2727%; height: 19.5909px;\"\u003eppm and % Vol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1875\" data-end=\"1922\" style=\"height: 19.5909px;\"\u003e\n\u003ctd data-start=\"1875\" data-end=\"1892\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eCarbon Dioxide\u003c\/td\u003e\n\u003ctd data-start=\"1892\" data-end=\"1922\" data-col-size=\"md\" style=\"width: 54.2727%; height: 19.5909px;\"\u003e\u003cstrong data-start=\"1894\" data-end=\"1920\"\u003e0–5% \/ 0–100% Vol. CO₂\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1923\" data-end=\"1964\" style=\"height: 19.5909px;\"\u003e\n\u003ctd data-start=\"1923\" data-end=\"1943\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eOxygen (Optional)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1943\" data-end=\"1964\" style=\"width: 54.2727%; height: 19.5909px;\"\u003e\u003cstrong data-start=\"1945\" data-end=\"1962\"\u003e0–25% Vol. O₂\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1965\" data-end=\"2014\" style=\"height: 39.1818px;\"\u003e\n\u003ctd data-start=\"1965\" data-end=\"1994\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 39.1818px;\"\u003eCarbon Monoxide (Optional)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1994\" data-end=\"2014\" style=\"width: 54.2727%; height: 39.1818px;\"\u003e\u003cstrong data-start=\"1996\" data-end=\"2012\"\u003e0–500 ppm CO\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2015\" data-end=\"2043\" style=\"height: 19.5909px;\"\u003e\n\u003ctd data-start=\"2015\" data-end=\"2031\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eFlow Velocity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2031\" data-end=\"2043\" style=\"width: 54.2727%; height: 19.5909px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2044\" data-end=\"2078\" style=\"height: 19.5909px;\"\u003e\n\u003ctd data-start=\"2044\" data-end=\"2054\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2054\" data-end=\"2078\" style=\"width: 54.2727%; height: 19.5909px;\"\u003e128 × 64 Backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2079\" data-end=\"2110\" style=\"height: 19.5909px;\"\u003e\n\u003ctd data-start=\"2079\" data-end=\"2089\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eBattery\u003c\/td\u003e\n\u003ctd data-start=\"2089\" data-end=\"2110\" data-col-size=\"md\" style=\"width: 54.2727%; height: 19.5909px;\"\u003eRechargeable NiMH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2111\" data-end=\"2151\" style=\"height: 19.5909px;\"\u003e\n\u003ctd data-start=\"2111\" data-end=\"2126\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd data-start=\"2126\" data-end=\"2151\" data-col-size=\"md\" style=\"width: 54.2727%; height: 19.5909px;\"\u003eVaries by application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2152\" data-end=\"2198\" style=\"height: 19.5909px;\"\u003e\n\u003ctd data-start=\"2152\" data-end=\"2167\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eData Storage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2167\" data-end=\"2198\" style=\"width: 54.2727%; height: 19.5909px;\"\u003e\u003cstrong data-start=\"2169\" data-end=\"2196\"\u003e1,000,000+ measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2199\" data-end=\"2227\" style=\"height: 19.5909px;\"\u003e\n\u003ctd data-start=\"2199\" data-end=\"2219\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2219\" data-end=\"2227\" style=\"width: 54.2727%; height: 19.5909px;\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2228\" data-end=\"2286\" style=\"height: 19.5909px;\"\u003e\n\u003ctd data-start=\"2228\" data-end=\"2252\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2252\" data-end=\"2286\" style=\"width: 54.2727%; height: 19.5909px;\"\u003e\u003cstrong data-start=\"2254\" data-end=\"2284\"\u003e14°F–104°F (-10°C to 40°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2287\" data-end=\"2346\" style=\"height: 19.5909px;\"\u003e\n\u003ctd data-start=\"2287\" data-end=\"2300\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"2300\" data-end=\"2346\" data-col-size=\"md\" style=\"width: 54.2727%; height: 19.5909px;\"\u003e\u003cstrong data-start=\"2302\" data-end=\"2344\"\u003e7.9 × 3.9 × 3.4 in (200 × 100 × 87 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2347\" data-end=\"2380\" style=\"height: 19.5909px;\"\u003e\n\u003ctd data-start=\"2347\" data-end=\"2356\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2356\" data-end=\"2380\" style=\"width: 54.2727%; height: 19.5909px;\"\u003e\u003cstrong data-start=\"2358\" data-end=\"2378\"\u003e2.8 lb (1.25 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2381\" data-end=\"2412\" style=\"height: 19.5909px;\"\u003e\n\u003ctd data-start=\"2381\" data-end=\"2401\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd data-start=\"2401\" data-end=\"2412\" data-col-size=\"md\" style=\"width: 54.2727%; height: 19.5909px;\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2413\" data-end=\"2438\" style=\"height: 19.5909px;\"\u003e\n\u003ctd data-start=\"2413\" data-end=\"2423\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 19.5909px;\"\u003eHS Code\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2423\" data-end=\"2438\" style=\"width: 54.2727%; height: 19.5909px;\"\u003e\u003cstrong data-start=\"2425\" data-end=\"2436\"\u003e9027.10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2439\" data-end=\"2467\" style=\"height: 14.5909px;\"\u003e\n\u003ctd data-start=\"2439\" data-end=\"2449\" data-col-size=\"sm\" style=\"width: 45.4338%; height: 14.5909px;\"\u003e\u003cstrong data-start=\"2441\" data-end=\"2448\"\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2449\" data-end=\"2467\" data-col-size=\"md\" style=\"width: 54.2727%; height: 14.5909px;\"\u003e\u003cstrong data-start=\"2451\" data-end=\"2465\"\u003eMBT-201052\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mission Bay Technologies","offers":[{"title":"Default Title","offer_id":44111892054081,"sku":"MBT-201052","price":6395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0002\/7466\/1441\/files\/GOLIATHRN.avif?v=1782943735","url":"https:\/\/www.missionbaytechnologies.com\/products\/natural-gas-leak-detector-for-utility-pipeline-inspection","provider":"Mission Bay Technologies","version":"1.0","type":"link"}